Chapter 3 — Developing and Using RFID Applications
42 IF2 Network Reader User’s Manual
This setting is equivalent to the SESSION BRI attribute. For more
information on this setting, see the EPCglobal Class 1 Gen 2
documentation.
Initial Q
(EPCglobal Class 1 Gen 2 tags only) Sets the initial Q parameter value
used by the Query command. Valid range is 0 to 15 (default is 4). If
you know there is only one tag in the field, set this attribute to 0 for
best performance.
This setting is equivalent to the INITIALQ BRI attribute.
Initialization Tries
Sets the maximum number of times the reader attempts to initialize a
tag. Valid range is 1 (default) to 254.
This setting is equivalent to the INITTRIES BRI attribute.
Schedule Option
Determines how antennas are switched during the inventory process.
This attribute controls the behavior of the inventory scheduling
parameters.
This setting is equivalent to the SCHEDULOPT BRI attribute.
ID Tries
Sets the maximum number of times the reader executes the identify
algorithm before a response is returned to a Read or Write command.
In practice, this is the number of times a tag ID attempt is made for
each antenna being used. Valid range is 1 to 254 (default is 3).
This setting is equivalent to the IDTRIES BRI attribute.
Antenna Tries
Sets the maximum number of ID Tries that the reader executes per
antenna. Valid range is 1 to 254 (default is 3).
This setting is equivalent to the ANTTRIES BRI attribute.