Chapter 4 — Managing, Troubleshooting, and Upgrading the IF2
IF2 Network Reader User’s Manual 65
To connect directly to the IF2 RFID module and verify operation
1 Make sure the RFID antenna is connected properly to the IF2.
2 Apply power to the IF2.
3 Use a communications program (such as HyperTerminal) to open
a TCP/IP connection to the IF2 with these parameters:
Configure the communications program to echo typed characters
locally and to send line feeds with line ends.
4 Press Enter. The BRI prompt (OK>) appears.
If the prompt does not appear, there may be a problem with the
RFID module or your connection to the module.
5 Type ATTRIB and press Enter. A list of the current settings for the
RFID module appears, indicating that the module is receiving
commands.
If the list does not appear, there may be a problem with the RFID
module.
6 (Optional) To verify that the RFID module is reading tags:
a Place a known good RFID tag within range of the antenna.
Parameter Value
IP Address IP address of the IF2
Port 2189