Chapter 3 — Configuring the CN30
112 CN30 Mobile Computer User’s Manual
connecting a USB cable between the USB connector in the back of the
CN30 Dock and your desktop computer.
Configuring 802.11b/g Radio Communications
The wireless CN30 Computer has an internal 802.11b/g radio to transfer
data using wireless communications. This section of the manual assumes
that you have already set up your wireless communications network includ-
ing your access points. If you are using a UDP Plus network, you also need
to have your Intermec Application Server communicating with a host com-
puter.
Your CN30 Computer supports TCP/IP and UDP Plus network protocols.
The next sections explain the parameters you need to configure for the
CN30 Computer to work in your wireless network.
Configuring the Network Parameters for a TCP/IP Network
In a TCP/IP network, the CN30 Computer communicates with a host
computer directly using TCP/IP. The access point acts as a bridge to allow
communications between the wired network and the wireless network.
To use wireless communications in a TCP/IP network, configure the Net-
work Name (SSID), Host IP Address, IP Settings (if not using DHCP),
and Network Port parameters on each CN30 Computer in the network.
Configuring the Network Parameters for a UDP Plus Network
In a UDP Plus network, the CN30 Computer communications with a host
computer through the Intermec Application Server.
The Intermec Application Server translates UDP Plus packets on the wire-
less network into TCP/IP packets on the wired network and vice versa. The
access point acts as a bridge to allow communications between the wired
network and the wireless network.
To use wireless communications in a UDP Plus network, configure the
Network Name (SSID), Controller IP Address, IP Settings (if not using
DHCP), and Network Port parameters on each CN30 in the network.
The easiest way to configure the network parameters on the CN30 Com-
puter is to use the Intermec Settings applet. For help, see “Configuring the
CN30 Computer With Intermec Settings” on page 108.
Make sure all components with antennas are at least 30 cm (1 ft) aport
when power is applied. Failure to comply could result in equipment
damage.
Attention: Assurez-vous que la distance entre tous les éléments avec
antennes soit d’au moins 30 centimètres (un pied) avant de faire la con-
nexion avec l’alimentation électrique, faute de quoi vous risquez
d’endommager votre installation.